POWER METERS
 
 



 
 

Microsoft are discontinuing this website service soon!

Please go to my new website

www.azurelectronics.com



 




 

At high frequencies, power is the best measure of signal amplitude because, unlike voltage and current, power remains constant along a lossless transmission line.

 

Power measurement accuracy is dependant on several factors: standing wave ratio (SWR); mismatch uncertainty; instrumentation uncertainty; calibration factor uncertainty; noise; zero drift; and for digital measurements, plus and minus one count ambiguity.  Of these, by far the largest source of uncertainty is SWR mismatch.  Further information is available in various HP Application Notes and Bench Briefs.

 

Power can be measured in various units including Watts and Decibels.  A RF Power & Voltage Conversion Chart is available providing conversion from power in dBm (+99dBm to -99dBm) giving power in Watts and voltage in Volts rms, dBv, dBmV & dBµV.

 

I have 4 different Power Meters available: digital; mixed analogue & digital; and analogue.

 
 
The HP 438A is a digital Power Meter with µP controlled dual channel inputs.  Choice of display in dBm, dB relative, Watts and % relative.
 
The measured ratio and difference of 2 inputs can be displayed.  The ratio or difference power readings of a single sensor input can also be displayed.
 
Manual or automatic ranging, zeroing, calibration, offsets, and panel settings memory are available.  For details see HP 438A Power Meter.
 
 
 
 

The HP 436A is a digital Power Meter with an analogue meter as well which shows fast changes in power levels to assist in ‘peaking’.

 

Choice of display in Watts, dBm or dB.  Auto ranging, automatic sensor recognition and auto zero features.

 

For details see HP 436A Power Meter.

 

 

 

 

 

 

The HP 435B is an analogue Power Meter.  It has internal automatic zeroing and a calibration factor adjustment.

 

It has a power range of 55dB with 10 full-scale ranges of: 3, 10, 30, 100 and 300µW; and 1, 3, 10, 30 and 100mW.

 

It is also calibrated in dB from -25dBm to +20dBm full-scale in 5dB steps.

 

For details see HP 435B Power Meter.

 
 
 
 
 
 
ModelPower RangePower RangeFrequencyCalibration
WattsdBRangeReference
HP 438A

100pW to

25W

-70dBm to +44dBm100kHz to 26.5GHz

1mW 0dBm

50MHz 50Ω

HP 436A

100pW to

3W

-70dBm to +35dBm

100kHz to

18GHz

1mW 0dBm

50MHz 50Ω

HP 435B

3µW to

100mW

-25dBm to +20dBm

100kHz to

18GHz

1mW 0dBm

50MHz 50Ω

 

NOTE: The power range depends on the power sensor being used.

 

 

Power Sensors

 

The Power Meters need power sensors which are connected via special cables.  There are 3 types of power sensors: diode; thermocouple; and thermistor.  Diode sensors are best.  These use a low-barrier schottky diode to achieve 100pW -70dBm sensitivity with low noise and drift.  They operate in the square law region so can be used to measure the true power of complex as well as CW (Continuous Wave) waveforms.

 

 

ModelPower RangePower RangeFrequencyNominal
WattsdBmRange Impedance
HP 8481A1µW to 100mW -30dBm to +20dBm10MHz to 18GHz 50Ω
HP 8481H30µW to 3W-15dBm to +35dBm10MHz to 18GHz50Ω
HP 8482A0.3µW to 100mW -35dBm to +20dBm100kHz to 4.2GHz50Ω
HP 8482H30µW to 3W-15dBm to +35dBm 100kHz to 4.2GHz50Ω
HP 8483A0.3µW to 100mW-35dBm to +20dBm100kHz to 2GHz75Ω
HP 8484A0.3nW to 10µW

-65dBm to

-20dBm

10MHz to 18GHz50Ω
 
 

The preferred models are: 8481A; 8481H & 8484ALimitations of the other models are marked in red.

 

 

 
 
NOTE: 8481A Maximum Input Power 300mW average or 15W peak for 2µs; and 8484A Maximum Input Power 200mW average or peak.
 

 

 

The Power Sensors need a special inter-connecting cable to the Power Meter,

either a HP 11730A or HP 8120-2263.   These use a special 8 pin plug at each end.

 

NOTE: Peak power measurement is possible using the HP 8900B with a bandwidth of 50MHz to 2GHz.  This needs a different power sensor using thermocouple or thermistor technology and a different cable.  This is unlikely to be required.


Attenuator

 
 
 
The 30dB Reference Attenuator HP 11708A is used with the HP 8484A so it can be connected directly to the Power Meters "Power Reference 1mW 50MHz Output to aid calibration.
 
 
 

 
Range Calibrator
 
 

 

 

 

 

The HP 11683A Range Calibrator (to be acquired) allows verification of full-scale meter readings on all ranges, as well as meter tracking.

 

 

 

 

 

 

 

 
 
References: HP Catalogue 1977, HP Application Notes and Bench Briefs
 
 
These are all power meters for RF applications.  Power can also be measured at mains frequencies with the Voltech. 
 
 
 
 
 